ENVY RT 1~3KVA
ENVY RT 1~3KVA

Overview

  • Cold start and ECO mode
  • Efficiency upto 90%
  • Emergency power off
  • Matching battey pack
  • Hot swappable battery
  • Rack convertible design
  • Tower convertible design
  • Wide input voltage range
  • Online double conversion
  • Optional powerful charger
  • Easy access of UPS status
  • High output power factor at 0.9F
  • Frequency converter mode is settable
  • Patented mimic LCD display may be rotated
  • Comprehensive display allows easy monitoring
  • Estimated remaining time displayed on the LCD
  • Smart SNMP works with either USB or RS232 together
  • Power shedding may turn off uncritical load in battery backup

Specifications

Input Battery
Nominal Voltage 200 / 208 / 220 / 230 / 240VAC Battery Type 1KVA: 12V/9AH 1.5KVA:12V/9AH    
Voltage Range 110~290VAC Numbers 2 3    
Frequency 45~65Hz (Auto detect)   2KVA: 12V/9AH 3KVA:12V/9AH    
Power Factor ≥0.98   4 6    
Bypass Voltage Range Max.voltage: +15% Typical Recharge 4 hrs recover to 90% capacity      
  (Optional +5%, +10%, +25%) Time        
  Min.voltage: -45% Charging Current 1A (Max)      
  (Optional -15%, -20%, -30%) Charging Voltage 1KVA: 27.4VDC±1% 1.5KVA: 41.0VDC±1%    
Frequency ±10%   2KVA: 54.7VDC±1% 3KVA: 84.1VDC±1%    
Generator Input Support Mode 1KVA: RTll-BR 04009 1.5KVA: RTll-BR 06009    
Output   Numbers 9AH x 4 9AH x 6    
Rating Voltage 200 / 208 / 220 / 230 / 240 VAC Dimensions(WxDxH) (mm) 440 x 86.5 x 430 440 x 86.5 x 430    
Power Factor 0.9 Net Weight (kg) 17.3 22.3    
Voltage Regulation ±1%   2KVA: RTll-BR 08009 3KVA: RTll-BR 012009    
Frequency 1.Utility mode: 50/60Hz   9AH x 8 9AH x 12    
  (Synchronized to mains)   440 x 86.5 x 542 440 x 86.5 x 720    
  2.Battery mode: 50/60Hz±0.1   29 41.1    
Crest Factor 3:1 Environmental
THDv Load<3% (Linear load) Capacity 1KVA 1.5KVA 2KVA 3KVA
  Load<5% (Non-linear load) Input IEC320 IEC320 IEC320 IEC320
Efficiency ≥90% Connection C14-10A C14-10A C20-16A C20-16A
System Features   Output  IEC320 IEC320 IEC320 IEC320
Transfer time Utility to Battery: 0ms, Connection C13-10A x 6 C13-10A x 6 C13-10A x 6 C13-10A x 6
  Utility to Bypass: <4ms Model/Capacity
AC Mode Load<108%~150%, 30 secs, Models ENVY RT      
  Load<150%, 300ms, then turn to fault Rating Capacity 1KVA 1.5KVA 2KVA 3KVA
  mode & give alarm Rating Power 900W 1350W 1800W 2700W
Battery Mode Load<108%~150%, 30 secs, Tempreature 0°C~40°C      
  Load<150, 300ms, then shut down Storage -25°C, +55°C      
  UPS & give alarm Tempreture         
Bypass Mode Load<108%~130%, 20 mins, Humidity 0%~90%RH (Non condensing)      
  Load<130%~150%, 2 mins, Altitude <1500m (Derating while>1500m)      
  Load<150%, 15 secs, then shut down Noise <50dB (At 1 meter)      
  UPS & give alarm Communication Smart RS232, USB port, RJ45 & SNMP card      
Audible & Visual Line failure, Battery low, Overload & Interface (Independent to RS232)      
  Systerm fault
Status LED & LCD Load, Battery, Input, Output &
  Operating mode information

SIMILAR PRODUCTS YOU MAY LIKE TO SEE

×